KYOCERA FS-C2526MFP Guia de Instalação Página 306

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 305
10-10
Troubleshooting > Solving Malfunctions
Printouts have black lines. Is the slit glass dirty? Clean the slit glass. 10-6
Images are skewed. Are the originals placed correctly? When placing originals on the platen,
align them with the original size
indicator plates.
3-10
When placing originals in the
document processor, align the original
width guides securely before placing
the originals.
3-11
Is the paper loaded correctly? Check the position of the paper width
guides.
3-2
When displaying an image
sent from the machine on the
PC, an image size is shrunk
vertically or horizontally.
Have you selected 200 × 100dpi
Normal or 200 × 400dpi Super for the
scan resolution?
Select a scan resolution other than
200 × 100dpi Normal or 200 × 400dpi
Super when sending an image.
3-44
Offset occurs. Run [Drum Refresh]. 9-25
Increase the adjustment value for [MC]
setting. Increase the adjustment value
1 level at a time from the current value.
If there is no improvement after the
value is increased by 1 level, increase
by 1 level again. If there is still no
improvement, return the setting to the
original value.
9-25
Part of the image is
periodically faint or blurred.
Decrease the adjustment value for
[MC] setting. Decrease the adjustment
value 1 level at a time from the current
value. If there is no improvement after
the value is decreased by 1 level,
decrease by 1 level again. If there is
still no improvement, return the setting
to the original value.
9-25
Irregular horizontal lines
appear in the image.
Decrease the adjustment value for
[MC] setting. Decrease the adjustment
value 1 level at a time from the current
value. If there is no improvement after
the value is decreased by 1 level,
decrease by 1 level again. If there is
still no improvement, return the setting
to the original value.
9-25
The altitude is 1500 m or
higher and irregular
horizontal white lines appear
in the image.
Set Altitude Adjustment to [High 1]. If
there is still no improvement, change
the value to [High 2].
9-25
Symptom Checkpoints Corrective Actions Reference